Basic Info.
Model NO.
GPEV180-FA750-M6
Transport Package
One Set in One Carton
Specification
1050*1650*300
Product Description
Features
Ultra high power 180KW, with separated six guns design, supports several flexible distributed charging mode.Using our own R&D module, 15KW or 30KW module are optional, applied to current and future high power vehicle types.Soft switching technology, the efficiency up to 96.4%. Full digital DSP controls, THD<3%.Using high-performance ARM chip control, 7-inch true color LCD touch screen, easy to achieve Human-machine information exchangeWith perfect protection function like: input over/under voltage protection, output over current protection, output over voltage protection, output short circuit protection, over temperature protection, battery anti-reverse protection, insulation detection protection, emergency stop protection.The charging rectifier module adopts active power factor compensation , power factor is 0.99.The rectifier module adopts no damage and hot -plugging technology, plugging and playing, the changing time less than 1min.Perfect AC side lightning protection design, to adapt to thunderstorm areas.Ultra-low radiation, safe and reliable.The design of dustproof and waterproof up to level IP54 to meet indoor and outdoor requirements.
System Statements
Ambient |
Parameter | Min. | Typ. | Max. | Unit | Remark |
Operating temp. range | -20 | 25 | 50 | °C | Certificated within this range |
Extreme operating temp. range | -40 | 25 | 55 | °C | -40°C ~-20°can be started with load. extended temperature:50 -55°C, The module outputs linearly at 4% / ° C |
Relative humidity | 5 | | 95 | % | No condensation on the surface |
Altitude | 0 | | 2000 | m | |
Input |
Parameter | Min. | Typ. | Max. | Unit | Remark |
Input mode | 3-Phase, 5 Wire (3Ph+N+E) | Note: the charger rectifier module without center line |
Nominal input voltage range | 323 | 380 | 437 | Vac | Nominal voltage, certified within this voltage range |
Input operating voltage range | 265 | 380 | 437 | Vac | The input voltage 315-265Vac is linearly reduced from 15KW to 5KW by 2% / V |
Max. input voltage | | | 500 | Vac | The module could not work but can't be damaged under this input voltage |
Max. input current | | | 350 | A | Low voltage full load ,each phase |
Max. input power | | | 196 | KW | Input 323Vac,output full load. |
Soft start time | 5 | | 15 | S | The nominal input voltage range is energized to the power supply and the output voltage rises to the set value. |
Power factor | >0.99 | Rated input, full load output |
>0.98 | Rated input, half load output |
Input current harmonic | THD<5% | Rated input, full load output |
THD<10% | Rated input, half load output |
Grounding method | Protected ground to the power supply case |
Output |
Parameter | Min. | Typ. | Max. | Unit | Remark |
Rated output voltage | 750 | Vdc | |
Rated output voltage range | 300 | | 750 | Vdc | Certificated within this output voltage range |
Rated output current | 12 | | 240 | A | 180KW charging mode |
6 | | 120 | A | 90KW charging mode |
4 | | 80 | A | 60KW charging mode |
2 | | 40 | A | 30KW charging mode |
Rated output power | | | 180 | KW | Max. power up to 150KW |
Stabilized voltage precision | -0.5 | | +0.5 | % | |
Ripple effective value | | | 1 | % | |
Dynamic response overshoot | -0.5 | | +0.5 | % | |
Efficiency | | | 95.8 | % | |
Noise | | | 65 | dB(A) | |
Current-sharing | | | 5 | % | Tested when the output current more than 50% |
Cooling | Forced air cooling |
Protection |
Parameter | Min. | Typ. | Max. | Unit | Remark |
Input over current protection | With input over current protection function, the input circuit breaker trip during protection. |
Input over voltage protection | 455 | | 465 | V | |
Input over voltage Protection recovery | 445 | | 455 | V | |
Input under voltage protection | 250 | | 264 | V | |
Input under voltage protection recovery | 280 | | 305 | V | |
Module over temp. protection | | 57 | | °C | Auto recovery after the module temperature reduced, |
Output over voltage protection | 765 | | 780 | V | Overvoltage lock, the module re-unlocked |
Output over current protection | | | 264 | A | Over current, or constant current |
Output short circuit protection | With short circuit protection function |
Fan fault protection | Any fan failure corresponding to the power module no output. |
Battery anti-reverse protection | When the output charging battery is reversed, the system has no output |
Insulation detection protection | With insulation detection protection function. |
System exception protection | During the charging process, in an emergency (such as starting the emergency stop switch, communication failure with the electric vehicle battery management system, control guidance failure, etc.), the charger should immediately disconnect the output contactor, and through the discharge circuit within 1S The charge interface voltage drops below 60VDC. |
Others requirements |
Parameter | Min. | Typ. | Max. | Unit | Remark |
Output current error | -1 | | 1 | % | The current less than 30A,the error ±0.3A |
Output voltage error | -0.5 | | 0.5 | % | |
DC meter error | | 0.5 | | Level | |
Low voltage auxiliary power supply | | 24±1% | | Vdc | Optional output 5A |
| 12±1% | | Vdc | Optional output 10A |
Charging cable length | | 5±0.2 | | m | |
Charging gun interface | Comply to GB/T20234.3-2015 |
Insulation |
Parameter | Requirements | Remark |
Input-output | 3535Vdc/10mA//1min | Remove the charging rectifier module, auxiliary power module and monitoring module while testing. Under normal atmospheric pressure, no breakdown and arcing within 1 minute |
Input-earth | 3535Vdc/10mA//1min |
Output-earth | 2121Vdc/10mA//1min |
Insulation resistance | Under normal atmospheric pressure, the relative humidity ≤ 90% of the environment, between the charged circuit and the charged circuit between the ground at 1000V DC voltage insulation resistance is no less than 10MΩ. |
EMC |
Parameter | Requirements | The reference standard |
ESD | Air discharge±8KV | GB/T 17626.2-2006(according to A) |
Contact discharge±6KV |
RS | Test frequency:80MHz~1000MHz; 800MHz~960MHz,1.4G~2.0GHz, Electric field strength:10V/m; Amplitude modulation:80%AM(1KHz) | GB/T 17626.2-2006(according to A) |
EFT/B | Power supply port, PE:2KV | GB/T 17626.4-2008(according to B) |
SURGE | 2KV±10% | GB/T 17626.5-2008(according to B) |
CE | CLASS A | EN55022 |
RE | CLASS A | EN55022 |
Mechanical |
Dimension of power cabinet | (W×H×D)1050 mm×1650 mm×300mm |
Weight of power cabinet | ≤210Kg(including module) ≤50Kg(Cabinet + Distribution,no module) |
Dimension of terminal cabinet | (W×H×D)450 mm×1000 mm× 200mm |
Weight of terminal cabinet | ≤30Kg |
Address:
2f Spring Velley Blcv, No. 10 Longchang Rd, Baoan, Shenzhen
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Electrical & Electronics, Lights & Lighting
Management System Certification:
ISO 9001
Company Introduction:
Techone was founded in 2003, a leading energy-saving company in the power supply industry. There′s an independent industrial park with 80, 000 square meters in Pingshan district, Shenzhen, China. With more than 500 employees and many core intellectual property rights.
We supplies digital power supply units and control solutions, for HID/LED/UV lighting and non-lighting applications. Nowadays, more than one and a half million our product have been working world-wide for general and special applications, such Hydroponics plant growing, street lighting, UV water processing and so on. Our patented devices and technology enable you to save upto 50% energy while delivering the same or more brightness.
We provide a complete line of products for HID/LED/UV system, with mutiple dimming or remote-control, universal AC/DC input and wide-range output power. OEM/ODM is also welcome. Our product has always passed UL certification. Good quality and service will be promised.