Basic Info.
Transport Package
One Set in One Carton
Specification
400mm*750 mm*650mm
Product Description
Features
Goldpower 30KW portable DC charger designed with single gun, the maximum power is 30KW.Using high-performance ARM chip control, 5-inch true color LCD touch screen, easy to achieve man-machine information exchangeWith perfect protective function: input over/under voltage protection, output over current protection, output over voltage protection, output short circuit protection, over temperature protection, battery anti-reverse protection, insulation detection protection, emergency stop protection.The charging rectifier module adopts full bridge soft switch technology, the efficiency up to 95% or more.The charging rectifier module adopts active power factor compensation technology, the value up to 0.98.Perfect AC side lightning protection design, to adapt to thunderstorm areas.Ultra-low radiation, safe and reliable. Pressure level, insulation class and EMC of the charger comply to relative requirements as per NB/T 33001-2010,and part of function designed as per "Typical design of EVSE"The design of dustproof and waterproof up to level IP54 to meet indoor and outdoor requirements.To prevent rain directly onto the equipment, the roof needs to be installed outdoor.
System Statements
1.1 GPEV30-750-S1 System Configuration
GPEV30-750-S1 charger consists of outdoor cabinet, HMI, power distribution unit, monitoring module and charging rectifier module. Specific matching module refers to following table:
Optional Configuration | Rectifier module | Optional number | Distribution | Monitoring system | Remark |
configuration | GPR75020A | 2pcs | AC input: 3-phase 5wire,63A/4P air switch; Anti--thunder:3-phase C pole DC output: the gun mode output maximum output current is 40A(DC+,DC-) EV auxiliary power supply: 12V10A/24V5A optional(A+,A-) | Monitoring system | See the module specifications for more detailed information |
1.2 GPEV30-750-S1 Charger Operating principle
The charger adopts three-phase five-wire input, through the input circuit breaker, into the charging rectifier module and auxiliary power supply module, the auxiliary power supply module provide auxiliary voltage (A +, A -)for the electric vehicle, C-class lightning protection in parallel the rectifier module input, to provide rated 20KA discharge current AC lightning protection.
The charging rectifier module converts the three-phase alternating current to HV DC and connects to the DC power distribution unit. According to the capacity requirements of the charger, the number of charging rectifier modules is optional.
2. DC power distribution unit will connect the DC output through the charging gun and electric vehicle charging interface, so as to charge the electric car. The DC charger consists of the monitoring system and at most 2 charging rectifier modules and monitoring HMI. Maximum output power is 30KW, output voltage 300Vdc~750Vdc adjustable.
Specifications
Ambient |
Parameter | Min. | Typ. | Max. | Unit | Remark |
Operating temp. range | -20 | 25 | 50 | °C | Certificated within this range |
Extreme operating temp. range | -40 | 25 | 55 | °C | -40°C ~-20°can be loaded with start, extended temperature:50 -55°C, The module outputs linearly at 4% / ° C |
Relative humidity | 5 | | 95 | % | No condensation on the surface |
Altitude | 0 | | 2000 | m | |
Input |
Parameter | Min. | Typ. | Max. | Unit | Remark |
Input mode | 3-Phase, 5 Wire (3Ph+N+E) | Note: the charger rectifier module without midcourt line |
Nominal input voltage range | 323 | 380 | 437 | Vac | Nominal voltage, certified within this voltage range |
Input operating voltage range | 295 | 380 | 437 | Vac | The input voltage 315-265Vac is linearly reduced from 15KW to 5KW by 2% / V |
Max. input voltage | | | 560 | Vac | The module could not work but can't be damaged under this input voltage |
Max. input current | | | 60 | A | Low voltage full load ,each phase |
Max. input power | | | 32 | KVA | Input 323Vac,output full load. |
Soft start time | 5 | | 15 | S | The nominal input voltage range rises to the set value of the output voltage. |
Power factor | >0.98 | Rated input, full load output |
>0.97 | Rated input, half load output |
Input current harmonic | THD<5% | Rated input, full load output |
THD<10% | Rated input, half load output |
Grounding method | Protective ground to the power supply case |
Output |
Parameter | Min. | Typ. | Max. | Unit | Remark |
Rated output voltage | 750 | Vdc | |
Rated output voltage range | 300 | | 750 | Vdc | Certificated within this output voltage range |
Rated output current | 2 | | 40 | A | |
Rated output power | | | 30 | KW | |
Stabilized voltage precision | -0.5 | | +0.5 | % | |
Ripple effective value | | | 1 | % | |
Dynamic response time | | | 200 | us | |
Dynamic response overshoot | -0.5 | | +0.5 | % | |
Efficiency | | | 95.8 | % | |
Noise | | | 65 | dB(A) | |
Current-sharing | -5 | | 5 | % | Tested when the output current more than 50% |
Cooling | Forced air cooling |
Protection |
Parameter | Min. | Typ. | Max. | Unit | Remark |
Input over current protection | With input over current protection function, the input circuit breaker trip during protection. |
Input over voltage protection | 455 | | 465 | V | |
Input over voltage Protection recovery | 445 | | 455 | V | |
Input under voltage protection | 250 | | 264 | V | |
Input under voltage protection recovery | 280 | | 305 | V | |
Module over temp. protection | | 56 | | °C | Auto recovery after the module temperature is reduced, |
Output over voltage protection | 765 | | 785 | V | Overvoltage lock, the module re-unlocked |
Output over current protection | | | 44 | A | Over current, or constant current |
Output short circuit protection | With short circuit protection function |
Fan fault protection | Any fan failure corresponding to the power module no output. |
Battery anti-reverse protection | When the output charging battery is reversed, the system has no output |
Insulation detection | With insulation detection protection function. |
System abnormal protection | During the charging process, in an emergency (such as starting the emergency stop switch, communication failure with the electric vehicle battery management system, control guidance failure, etc.), the charger should immediately disconnect the output contactor, and through the discharge circuit within 1S The charge interface voltage drops below 60VDC. |
Others requirements |
Parameter | Min. | Typ. | Max. | Unit | Remark |
Output current error | -1 | | 1 | % | |
Output voltage error | -0.5 | | 0.5 | % | |
DC meter error | | 0.5 | | Level | |
Low voltage auxiliary power supply | | 24±1% | | Vdc | Optional output 5A |
| 12±1% | | Vdc | Optional output 10A |
Input cable length | 7 | | | m | Optional length |
Charging cable length | 5 | | | m | Optional length(don't contain the length of gun) |
Charging gun interface | Comply to the latest national requirements of GB/T20234.3-2015 |
Insulation |
Parameter | Requirements | Remark |
Input-output | 3535Vdc/10mA//1min | Remove the charging rectifier module, auxiliary power module and monitoring module while testing. No breakdown and arcing within 1 minute under normal atmospheric pressure |
Input-earth | 3535Vdc/10mA//1min |
Output-earth | 2121Vdc/10mA//1min |
Insulation resistance | Under normal atmospheric pressure, the relative humidity ≤ 90% of the environment, between the charged circuit and the charged circuit between the ground at 1000VDC voltage insulation resistance of not less than 10MΩ. |
EMC |
Parameter | Requirements | The reference standard |
ESD | Air discharge±8KV | GB/T 17626.2-2006(according to A) |
Contact discharge±6KV |
RS | Test frequency:80MHz~1000MHz; 800MHz~960MHz,1.4G~2.0GHz, Electric field strength:10V/m; Amplitude modulation:80%AM(1KHz) | GB/T 17626.2-2006(according to A) |
EFT/B | Power supply port, PE:2KV | GB/T 17626.4-2008(according to B) |
SURGE | 2KV±10% | GB/T 17626.5-2008(according to B) |
CE | CLASS A | EN55022 |
RE | CLASS A | EN55022 |
Mechanical |
Dimension | (W×H×D)400 mm×750 mm×650mm |
Weight | ≤60Kg(including module) |
Address:
2f Spring Velley Blcv, No. 10 Longchang Rd, Baoan, Shenzhen
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Electrical & Electronics, Lights & Lighting
Management System Certification:
ISO 9001
Company Introduction:
Techone was founded in 2003, a leading energy-saving company in the power supply industry. There′s an independent industrial park with 80, 000 square meters in Pingshan district, Shenzhen, China. With more than 500 employees and many core intellectual property rights.
We supplies digital power supply units and control solutions, for HID/LED/UV lighting and non-lighting applications. Nowadays, more than one and a half million our product have been working world-wide for general and special applications, such Hydroponics plant growing, street lighting, UV water processing and so on. Our patented devices and technology enable you to save upto 50% energy while delivering the same or more brightness.
We provide a complete line of products for HID/LED/UV system, with mutiple dimming or remote-control, universal AC/DC input and wide-range output power. OEM/ODM is also welcome. Our product has always passed UL certification. Good quality and service will be promised.